Industrial Process Electric Heaters - Products Flanged Immersion Heaters Screw-Plug Heaters Duct Heaters Circulation Heaters Over-the-Side Heaters Finned Tubular Heaters Pipe Insert Heaters Tubular Heaters and Elements Temperature/Power Control Panels
Search this site:

Profile Literature Links Sitemap Contact Us
 

Duct and Air Process Heaters:

Air Process Heater Duct air heater
Duct and Air Process Heaters


PRODUCT DESCRIPTION

Duct heaters from National Plastic Heater are composed of, tubular, finned tubular or open coil heating elements that are either flanged or inserted in the duct. A duct air heater is generally an assembly of tubular heating elements ready to mount into a duct but it can also be an open-coil resistance wire assembly mounted into a duct. Tubular Heating of proper rating, material and shape can be used in most heating applications. Finned Tubular Air Heaters are designed to suit particular applications. There features include: steel sheath material, high quality MGO compacted to provide maximum heat conductivity and optimum dielectric strength, 80/20 resistance wire sized to provide the lowest watt density giving long superior life. Duct Heaters are used in a variety of air and gas heating applications. These are intended to be installed in existing ducting and can be mounted in any direction. Thermostats, thermocouples and high limit switches can be incorporated.

Industrial Duct Air Heaters | Duct Air Heaters Duct Heaters Air Process Heaters Specifications.pdf

Industrial Duct Air Heaters | Duct Air Heaters Duct Heaters Air Heaters Wiring Diagrams.pdf

Forced Air Duct Heater - for Industrial Process Heating Only

Ovens often require re-circulated air, or forced circulation, to perform the desired heating task. A duct heater mounted in this re-circulated air stream is an effective way to provide this heat, without having any electrical connections inside your oven.


Typical Applications

heat treating, up to1000F (540C)

curing

baking

Industrial Duct Air Heaters | Duct Air Heaters drying

batch heating

conveyor systems


Typical Air Heat Calculation

kW =

SCFM x temperature rise
3000

kW - kilowatts
SCFM - standard cubic feet per minute
Temperature rise - number of degrees Fahrenheit increase required


Typical Options and Features for Duct Heaters:

NEMA 1 or NEMA 4 electrical enclosures

Industrial Duct Air Heaters | Duct Air Heaters 304 or 316 stainless steel flange

stainless steel or Incoloy sheath materials

Hi temperature limit thermocouples

purged electrical enclosures for hazardous areas

Telephone: 905-859-8225 Facsimile: 905-859-4691


How To Order Duct, Air Process Heaters

Quotation Request Form

(Please complete the fields below by looking at the drawing above)

Specify the following measurements by referring to sketch above:
Specify for:
A B
C D
E F
G H
J K
L
Specify Sheath Material:
Specify terminal housing:
Specify temperature sensor type:
First Name Last Name
Company Name Position
Address City/State/Province
Zip/Postal Code Country
Phone Number Fax Number
Toll Free Number Email
Web Site OEM Distributor Process User
Quotation Request Required Delivery Date
have a salesperson contact me

 




Telephone: 905-859-8225        Facsimile: 905-859-4691

sales@nphheaters.com

Toll Free: 1-877-674-9744

Our industrial process electric heaters...

Our industrial process electric heaters consist of the following product categories: flanged immersion heaters, screw-plug immersion heaters, over-the-side heaters, circulation heaters, duct or air process heaters, pipe insert heaters, tubular heaters , finned tubular heaters and Temperature Control Power Panels.

Industrial process heaters are available with adjustable thermostats, digital temperature controls; SCR, mercury relay or mechanical temperature control power panels with process and high limit thermocouples.

Industrial process heaters from National Plastic Heater, Sensor and Control Inc. are Hydro approved and CSA or C UL recognized. Terminal enclosures can be NEMA 1 (General Purpose), NEMA 4, ( Moisture resistant) NEMA 4X (Corrosion/Moisture Resistant), NEMA 7 (explosion proof) and NEMA 12 (Dust and Oil Resistant).

Industrial heater sheath materials like Titanium, Incoloy, Stainless Steel, Steel, and Copper can be used as required for specific applications. Standard Flanged Immersion Heaters have a 150 lbs flanges but 300, 600 and 1500 lbs flanges are also available.

Below a brief description of most of our industrial process heaters line-up:

Screw plug immersion heaters consist of hairpin bent tubular elements brazed or welded into a screw plug and provided with terminal boxes for electrical connections.

Screw plug immersion heaters are screwed directly through a threaded opening in a tank wall or through matching pipe coupling, half coupling or welding flange.

Circulation Heaters offer the following: High efficiency heat transfer, Pressure ratings to 600 lbs, ANSI Standard NPT or ANSI Class 150 connections, Heaters could be screw plug or flanged, Stainless steel construction with Canadian Vessel Registration, Various housing options available NEMA 4, 4X, explosion proof,

Suitable for steam, oils, chemicals, gases, corrosive solutions.

Heating using pipe insert heaters: A pipe insert heater uses an element inserted into a sealed pipe. The advantage to the pipe insert heater is that the element is isolated from the process. This allows the element to be removed without draining the tank, isolates hazardous or corrosive materials from deteriorating the element, and if sized properly may allow the heat to be distributed over a larger surface area reducing the watt density exposed to the process.

Over-the-side immersion heaters are designed for vessels where through the side immersion heaters cannot be conveniently installed. These heaters are installed through the top of the vessel with the heated portion of the unit along the side or at the bottom of the tank.

NPH Tubular heaters can be used in their straight form or bent into various shapes.

Tubular heaters can be used in free air, clamped to a surface, placed inside a groove or cast into metal.

Finned tubular heaters offer distinct advantages over open coil heaters: (a) they are safer to operate in that the risk of fire or electrical shock are minimized; (b) they have a much longer service life; and (c) they are more rugged requiring less maintenance than open coil heaters.

Duct heaters from National Plastic Heater are composed of, tubular, finned tubular or open coil heating elements that are either flanged or inserted in the duct. Duct air heaters are generally an assembly of tubular heating elements ready to mount into a duct but it can also be an open-coil resistance wire assembly mounted into a duct.

Temperature Control Power Panels, for a wide variety of applications are designed and engineered by National Plastic Heater, Sensor and Control Inc. Entire systems are available for the most complex process heating control applications that require electric heaters, temperature controls, and temperature sensors. Control power panels can be built with as little as one zone to as many as 36 or even more temperature control sensing points.